7) Wash bottles
8) Strong magnet
9) Incubator (50EC)
10) Suction filtration apparatus with Buchner or Hirsch funnel
11) Ruled filter paper. Filter paper should be larger than funnel plate.
12) Ashless filter paper. Filter paper should be larger than funnel plate.
13) Emulsifier (Igepal CO 730; GAF Corp.)
14) 1 N HCl
15) Concentrated HCl
16) Concentrated NH4OH
17) Pepsin (1:10,000 - Difco Laboratories or equivalent)
18) Triton X-114 (Sigma Chemicals)
19) 1% sodium lauryl sulfate solution
20) Alcohol, 95%
21) Petri dishes to suit size of filter paper used
22) Fine, non-magnetic probe (platinum or glass recommended)
23) Glycerol-95% ethanol mixture (1:1)
24) Stereoscopic microscope (10-30x)
25) US standard No. 230 sieve
26) Platinum crucible
27) Muffle oven
28) Desiccator
The examination shall be carried out in accordance with the following instructions.
5.1 Analytical Units
5.1.1 In a random fashion from a sample unit weigh 225 g. This 225 g constitutes an analytical unit.
5.1.2 Repeat step 5.1.1 for remaining two sample units.